Start by pressing “OK” once -> screen should read “LANG”, then show current language setting

  Language setting should be “EnG”. If it is not, use +/- to scroll to “EnG”, then press “OK”

  After changing the language setting, or if language is already correct, exit menu until you’re back at the main screen

  DO NOT continue pressing “OK” after selecting the language

Next, configure the gate logic settings

  Press “OK” twice in rapid succession

  You should see “hALT” or “ALT” appear on the screen. Press “OK”

  You should see something like “FoLLoW thE USEr GUIdE” scroll across the screen. Press “OK” to skip

  You should see “PArAM” appear on the screen. Use +/- to navigate down to “LoGIc” and press “OK”

  We are now in the logic configuration screen

  Use +/- to scroll to “tcA” (Automatic Closing Time). Press “OK” to edit this setting

    The “tcA” setting must be “000” (disabled). If it is not, use +/- to set it to “000”

    Press “OK”. You should see “PRG” flash across the screen, then return you to the logic configuration screen

  Use +/- to scroll to “FASt cLS” (Fast closing). Press “OK” to edit this setting

    The “FASt cLS” setting must be “000” (disabled). If it is not, use +/- to set it to “000”

    Press “OK”. You should see “PRG” flash across the screen, then return you to the logic configuration screen

  Use +/- to scroll to “IC1” (IC 1 input configuration, corresponding to terminals 60/61). Press “OK” to edit this setting

    The “IC1” setting must be “002” (open gate). If it is not, use +/- to set it to “002”

    Press “OK”. You should see “PRG” flash across the screen, then return you to the logic configuration screen

  Use +/- to scroll to “AUX3” (AUX 3 output configuration, corresponding to terminals 26/27). Press “OK” to edit this setting

    The “AUX3” setting must be “012” (barrier status output). If it is not, use +/- to set it to “012”

    Press “OK”. You should see “PRG” flash across the screen, then return you to the logic configuration screen